AOV Kit 9 - Fan Skid & HMI Control Panel for Mechanical Smoke Shaft
AOV Kit 9 - Fan Skid & HMI Control Panel for Mechanical Smoke Shaft
  • AOV Kit 9 - Fan Skid & HMI Control Panel for Mechanical Smoke Shaft
  • AOV Kit 9 - Fan Skid & HMI Control Panel for Mechanical Smoke Shaft

AOV Kit 9 - Fan Skid & HMI Control Panel for Mechanical Smoke Shaft

Product Manufacturer: easivent

A skid-mounted unit comprising fans, dampers, and controls designed specifically for smoke shaft applications. Extract fans will be axial high temperature fans manufactured from hot dipped galvanized steel sheet.
The fan assembly will contain a weatherproof discharge, a flexible connector, a gravity shut-off damper, and a galvanized steel plenum section connected to the builder’s work roof upstand above the extract shaft.
The fan assembly will be mounted onto skids fitted with adjustable feet for mounting on a suitably prepared roof area.
The main system control panel is to be located on the fan skid arrangement and prewired to the fans and dampers. The exhaust should be positioned a minimum of 5m from the stairwell vent to prevent smoke being drawn into the stairwell.
AOV Kit 8 - 1.5m² Louvered Smoke Shaft Vent & ControlsAOV Kit 8 - 1.5m² Louvered Smoke Shaft Vent & Controls

All fans are tested to the latest internationally recognised standard IS05801 Part 1, installation category D for aerodynamic performance and BS848 Part 2 (1985) for acoustic performance. The fans and motors are rated at 300°C for two hours and are fully tested and certified to the requirements of EN12101-3. The fans are mounted in series onto a pre-assembled module using anti-vibration mounts.

System name: Fläkt Woods E3 Smoke Shaft

Scope: Sngle stair building from three to 20 storeys high
Fan: 630mm dia high temperature axial
Duty: 6m3/s
Static pressure: 300 Pa
Control centre: One power module 17A (7.5kW)

Fire Fighting Control: 7" Touch Screen Control Panel
Voltage: 400V three-phase Input
Regulated to: EN12101 and Approved Document B
Location: Roof mounted
Electrical wiring: FP200 for sensors and devices, FP400 for power supplies to plant

Weight: 500Kg

N.B. Non-stock versions will have an approximate manufacture time of 4-6 weeks plus 4 days for transport.

 

Get your AOV kit brochure

more

aov hatch type vents louvered smoke control smoke ventilation stair ventilator ventilation

£19,940.00